As expansion module
Connect the RS-485 slave port to an Adquio controller or another compatible Modbus RTU master. The controller collects the inputs and sends the orders to the outputs.
Expansion modules
Gather inputs and outputs in an expansion module connected by Modbus RTU. Adapt signal acquisition and control commands to each zone of the facility.

INPUTS, OUTPUTS AND MACHINE CONTROL
Connect sensors, PT1000 probes, relays and analogue and digital signals for exchangers, chillers, evaporator and condenser units, air handling units and other equipment.
Adquio Multi IOs combine inputs and outputs with Modbus RTU communication to simplify machine integration and centralise your signals.

Connect the RS-485 slave port to an Adquio controller or another compatible Modbus RTU master. The controller collects the inputs and sends the orders to the outputs.
For manufacturers and dedicated applications, custom programming allows the machine to be governed without an additional programmable controller. The master port allows you to incorporate a screen or a compatible thermostat to consult statuses, set setpoints and perform manual control. This mode requires specific study and programming.


| Supply voltage | 24 V DC |
|---|---|
| Current | 130 mA |
| Maximum allowed voltage | 28 V DC |
| Peak start-up current | 150 mA |
| slave port | 1 · RS-485 · Modbus RTU |
|---|---|
| Master port | 1 · RS-485 · Modbus RTU |
| Communication speed | 9600–19200 bps |
| Address | DIP switches |
| Configurable inputs | 8 · AI/DI |
|---|---|
| Analogue ranges | 0–10 V / 0–24 V |
| Logic level 1 digital | > 4,7 V |
| Resolution | 12 bits |
| 4–20 mA inputs | Requires DIN rail converter |
| Temperature inputs | 4 · PT1000 |
|---|---|
| Resolution | 15 bits |
| Adjustment | Software-adjustable |
| dry contacts | 5 |
|---|---|
| Contact current | 10 A |
| Contact voltage | 250 V AC |
| Durability | More than 100,000 switching operations |
| Outputs | 4 · 24 V · power transistors |
|---|---|
| Maximum load | 2 A |
| Outputs | 4 · 0–10 V |
|---|---|
| Resolution | 12 bits |
| Maximum load | 10 mA |
| Mounting | Horizontal · DIN 35 mm |
|---|---|
| Protection | IP20 |
| Operating temperature | 0–60 °C |
| Storage and transportation | −40–70 °C |
| Relative humidity | ≤ 95% no condensation |
| Status LED | 3 · Power, Online, Error |
| Safety and health | EN ISO 13849-1: 2015 EN ISO 13849-2: 2012 EN 62061:2005 + A1:2013 + A2:2015 EN 60950-1:2006 EN 62311:2008 |
|---|---|
| EMC | EN 61000-6-4:2007 + A1:2011 EN 61000-6-2:2005 ETSI EN 301 489-1 v2.2.0 ETSI EN 301 489-17 v3.2.0 |
| RoHS | EN 50581: 2012 |
Measurements and statuses arrive at the controller; orders return to the outputs via Modbus RTU.
Connect probes, sensors, relays and actuators to the corresponding inputs and outputs.

The module collects measurements and statuses and switches or regulates the connected outputs.
Use a compatible Modbus RTU master, such as Adquio Mini, to coordinate logic, schedules and other building systems.
Use controller variables in control, monitoring, and historical data analysis interfaces.
Map sensors and actuators to Adquio Multi IOs inputs and outputs. We will help organise signals, variables and programming for the required function.