Probes and sensors

Adquio Multi Sensors

Gather environmental measurements on a device connected by Modbus. Use Adquio Multi Sensors variables to relate comfort, space conditions and control.

Adquio Multi Sensors
Adquio Multisensors Modbus

Adquio Multi Sensors is a compact device that integrates Temperature, Humidity, Co2 and particle probes. It is connected by Modbus RTU and is powered between 12 and 24V. Its main characteristics are: its small size and its reliability. Up to 64 probes can be configured on the same bus. By default, they are configured at 9600 Baud N81, but you can change any of the parameters through Modbus.

All sensors will arrive calibrated, they are additionally adjustable by software independently.

They are fixed to the wall with double-sided 3M or with screws (not supplied). 

How to open it

Adquio ecosystem sensors connected by Modbus have their terminals inside the enclosure, leaving a clean exterior with no exposed wiring after installation.

Therefore, in order to connect it, it is necessary to open it, and to do this, you only need to use a flat screwdriver (no larger than 2.5 mm in diameter), placing it in the position provided for this, and pull up the top cover.

How to open Adquio Sensors
Conexiones Adquio Sensors

Internal connections

Adquio Multi Sensors have duplicate wiring connections. This allows for easy bus installation, since you can use one set of connectors as input, and the other as output to the next device.

The terminals use push-button connections. Press each terminal’s button with a screwdriver tip, insert the wire or ferrule, then release the button to secure it.

These are the connector values:

  1. Positive terminal power supply from 12 to 24v direct current.
  2. Negative power supply terminal.
  3. Pole A or positive of the 485 communication bus.
  4. Pole B or negative of the 485 communication bus.
  5. Micro switch block to set the modbus address of the device.

Modbus Address Settings

The attached table shows the possible combinations for the Modbus address of your probe. It is possible to install up to 64 probes on the same bus.

In the image we show you the first 16, you can see the complete table in the datasheet available in the header.

Adquio Sensors Modbus address
Adquio Multi Sensors Modbus registers

Modbus Register Table

In the attached table you can see the Modbus register configuration, it is also available in the product datasheet available in the header.

Certifications

Safety and Health

EN ISO 13849-1: 2015

EN ISO 13849-2: 2012

EN 62061:2005 + A1:2013 + A2:2015

EN 60950-1:2006

EN 62311:2008

EMC

EN 61000-6-4:2007 + A1:2011

EN 61000-6-2:2005

ETSI EN 301 489-1 v2.2.0

ETSI EN 301 489-17 v3.2.0

Connect your project to the entire Adquio ecosystem.

Define which environmental conditions to monitor in each room. We will help integrate Adquio Multi Sensors readings into controls, alarms and indicators.