Probes and sensors

Adquio LoRa Sensors

Bring environmental measurements to your control system using LoRa communication. Review the configuration, power, and coverage conditions of each installation.

Adquio LoRa Sensors
Adquio Sensors LORA

Adquio LORA Sensors is a compact device that integrates Temperature and Humidity probes. For its connection, it uses LORA technology, which allows outstanding wireless communication within buildings, passing through walls and slabs without major problems.

It is powered by one or two 18650 rechargeable batteries, if you use 2 their duration can be up to 8 years. It is important to note that these batteries, once used, can be recharged and used again without problem.

Its main characteristics are: its small size and its reliability. This probe needs a receiver, said receiver connects via Modbus RTU to any Adquio or to any controller from another brand that supports this protocol.

 

How to open it

Adquio ecosystem LoRa sensors have their connections inside the enclosure, leaving a clean exterior with no exposed wiring after installation.

Therefore, in order to connect it, it is necessary to open it, and to do this, you only need to use a flat screwdriver (no larger than 2.5 mm in diameter), placing it in the position provided for this, and pull up the top cover.

How to open Adquio Sensors
Inside Adquio LoRa Sensors

Inside the sensor

Adquio LORA sensors can take either one or two 18650 batteries, if you want a very long battery life you should put two units in it.

Within the probe there are several points that deserve our interest:

  1. Battery position: observe the polarity markings on the circuit board. If the batteries are inserted incorrectly, the device is protected against damage but will not operate.
  2. Link jumper. You will receive your probe with a Jumper, but it will be disconnected. If you connect it, it will put the probe in link mode with the receiver.
  3. Link confirmation LED. It lights up steadily when you insert the jumper, this may take up to a minute, since the probe will be in sleep mode. Once this time has passed, the LED will turn on and flash once, this will indicate that the pairing message has been sent.  When successfully paired, this LED will flash 4 times in a row. Once this happens you must remove the jumper that you had connected in the previous step.

Certifications

Safety and Health

EN ISO 13849-1: 2015

EN ISO 13849-2: 2012

EN 62061:2005 + A1:2013 + A2:2015

EN 60950-1:2006

EN 62311:2008

EMC

EN 61000-6-4:2007 + A1:2011

EN 61000-6-2:2005

RoHS

EN 50581:2012

Connect your project to the entire Adquio ecosystem.

Tell us where measurements are needed without running a communication cable. We will help review LoRa probes, coverage, the receiver and control variables.