ADQUIO SUPPORT · FREQUENTLY ASKED QUESTIONS

Answers for integration, configuration and control.

Find practical guidance on Adquio controllers, platforms and integrations. Search for a keyword or choose the topic of your enquiry.

46 questions organised by topic
Professional preparing a control-system integration

46 questions available

SCADA, data and management

7 questions
How do I display hourly energy consumption?

Record the energy or power variables, select a period and choose an appropriate visualisation. Distinguish instantaneous power from the energy consumed during each interval.

Adquio Analytics provides dashboards for studying trends. Adquio Cloud BMS supports analysis and comparisons across centrally managed installations.

Training: charts and reports in Adquio SCADA ↗

How do I control Casambi from SCADA and see its actual state?

Lithernet gateways bring compatible Casambi variables into Adquio. Export the required variables to Adquio SCADA Server and bind their values to indicators, shapes or controls.

Virtual variables and programming can coordinate actions, such as activating two scenes and a relay-controlled luminaire from one button.

Use the corresponding device or group variable to display actual feedback. Distinguish an issued command from its confirmation: updates from other controls may be delayed, particularly for scene-related states.

Training: using variables in Adquio SCADA ↗

How do I prepare charts and reports in Adquio SCADA?

Prepare the variables you need and configure recording when historical information is required. Define the data and reporting period, then use the tools available in your SCADA version.

You can complement operational monitoring with Adquio Analytics for dashboards and trend analysis.

Training: charts and reports in Adquio SCADA ↗

What must I configure to connect SCADA and a controller?

Prepare the controller variables and enable their export. Review data-type conversion where necessary, then configure the SCADA connection to import and use those variables.

The three training steps are Exporting values in Adquio, Converting variables for SCADA and Importing and using variables in Adquio SCADA Server / Cloud. Also check connectivity and access permissions.

Open the variable integration training ↗

How do Adquio Analytics and Adquio Cloud BMS differ?

Adquio Analytics specialises in dashboards, visualisation and historical data analysis. Adquio Cloud BMS focuses on managing, supervising and comparing multiple installations.

They complement each other. Choose according to whether you need detailed data analysis, building-portfolio management or both.

Can I compare energy consumption per square metre across buildings?

Yes. Adquio Cloud BMS can consolidate data from different installations and define comparable indicators, such as energy consumption divided by the corresponding floor area.

Use consistent periods, units, floor-area definitions and measurements. Project formulas and calculations can incorporate additional operational or technical variables to interpret differences between buildings.

Can I locate equipment on a representation of the building?

Adquio Supervisor organises devices by building, floor and space and relates them to a spatial 3D representation. This helps locate equipment and review states and incidents in context.

That view can complement operational SCADA control and historical data in Adquio Analytics. Simulation or prediction capabilities require specific models and development.

Configuration and programming

6 questions
How do I update hour and minute variables?

In Programming, create a periodic event, for example Update-DateTime, and write the hours and minutes to the corresponding memory variables. Check that those variables exist and that the controller clock and time zone are correct.

let date = new Date();
devices.writeFuture('memory', 'hora_actual', date.getHours());
devices.writeFuture('memory', 'min_actual', date.getMinutes());
Is event-driven programming written in JavaScript?

Yes. Adquio controller programming uses JavaScript and its runtime functions to read variables, write values and respond to events. Consult the controller API documentation for the available operations.

How do I add a device to a controller?

Define the connection and protocol, name the device and configure its variables. Depending on the equipment, you may need an IP address, slave address, registers, data types or other settings.

Start with the available Adquio device configuration profiles and adapt them to your installation. Check communication before using the variables in automation.

How many users can use the system?

Capacity depends on the controller or platform, concurrent connections, requested data and update frequency. Define the required user profiles and permissions and assess the project’s expected load.

A concurrent-user recommendation for one model is not a universal limit for the whole ecosystem.

What types of alarms can I manage?

Alarms can originate from integrated equipment, communication issues or conditions defined through programming.

How each alarm is displayed and handled depends on the configured logic and platform. Adquio Supervisor helps consolidate incidents and locate equipment requiring attention.

Can controllers in different zones work with a central server?

Yes. A tree architecture distributes control across zones, machines or systems and organises synchronisation with a central Adquio Server.

For larger areas, Adquio Micro Server can serve as an intermediate controller. Define shared variables, each device’s responsibilities and the functions that must remain local.

Casambi and integration

8 questions
Can I control several Casambi networks from one interface?

Yes. Connect the networks through the required Lithernet gateways and integrate their variables into Adquio. You can then organise lighting, groups, scenes and states by building, floor or zone in a Adquio SCADA Server or Adquio SCADA Cloud interface.

The operator can work with a consolidated view. Size the installation according to its networks, equipment and required monitoring or control functions.

Can I combine Casambi automation with manual control?

Yes. You can retain Casambi automation and add manual controls through Adquio, touchscreens or SCADA. Define command priorities and how automatic operation resumes.

Automatic operation can resume through a user action, schedule or programmed condition, depending on the integration. A common strategy prevents conflicting commands to the same zone.

Can I access several Casambi networks through an API?

Adquio API lets you integrate an installation’s Casambi networks through a common access point and one API key. External applications and platforms can use the data and commands exposed by the integration.

Define the variables to read or control and review API documentation, authentication and permissions before developing the application.

Can I integrate Adquio with another manufacturer’s BMS?

Yes, through interfaces and protocols supported by the project. Adquio can consolidate variables from different systems and make them available to an existing management platform.

For publishing variables over BACnet/IP, Adquio BACnet Exporter supports that integration, including consolidated variables from multiple Casambi networks. Define the points, data types and read/write permissions required by the BMS.

How does a KNX installation connect to Adquio?

Adquio KNX Gateway uses KNXnet/IP to communicate with a KNX/IP interface or router. Map group addresses and their DPTs to Adquio variables and configure the required communication direction.

The KNX/IP interface or router provides the link to the KNX bus. The Adquio gateway does not connect directly to the TP bus cable.

Can I connect Matter devices and share variables with that ecosystem?

Adquio MatterLink can bring compatible Matter devices into Adquio and expose selected variables through its Matter bridge.

Check supported device types, pairing and the receiving platform’s capabilities. Bridge exposure uses the functions implemented for each variable type.

Can Casambi, DALI and KNX work together in one building?

Yes. Integrate Casambi through Lithernet, DALI through a compatible gateway and KNX through Adquio KNX Gateway and a KNX/IP interface.

The controller relates variables to coordinate actions, such as a combined lighting and HVAC scene. Each technology retains its own functions. Define priorities and communication-loss behaviour for consistent coordination.

Does PowerTrace measure or estimate lighting consumption?

Adquio PowerTrace for Casambi calculates estimates from luminaire characteristics and available operating information. These estimates support analysis by zone or period.

Use suitable metering when physical or certified measurement is required. Adquio Analytics can help present and analyse the project’s energy data.

Connectivity and remote access

7 questions
Can I access controller configuration through remote management?

Distinguish data supervision from access to the device’s configuration interface. A management platform lets you view and operate integrated functions.

To reach a controller’s web interface or a local Adquio SCADA Server remotely, use the installation’s authorised remote-access arrangement, such as Adquio Nexus.

Can I connect to Adquio over Wi-Fi?

It depends on the model and configuration. Devices such as Adquio Mini and Adquio Lite provide an access point to assist configuration. Check the installed model’s activation conditions and supported Wi-Fi use.

For normal operation, use the network connection specified in the installation design.

What options are available for wireless communication?

The solution depends on the task. LoRa sensors can be integrated through Adquio LoRa Sensors Gateway. Other devices and systems use Wi-Fi or gateways suited to their technology.

For Internet access, use the project’s specified router or modem, including mobile connectivity where appropriate. Define coverage, power and communication availability before selecting equipment.

Can I configure or program Adquio remotely?

Yes, when authorised remote access to its interface is available. Adquio Nexus lets a person access remote equipment for supported configuration, programming and diagnostic tasks.

Adquio Bridge serves a different purpose: it connects equipment to other equipment over the Internet. Choose the service that fits the project architecture.

Do I need Adquio Cloud BMS for monitoring and control?

An architecture can combine local services and cloud platforms. Controllers run the local logic configured on them.

Adquio Cloud BMS complements these tools with centralised management and comparisons across multiple installations. Define the project requirements before selecting services.

How is access to a device protected?

Access requires connectivity and the credentials of an authorised user. Set appropriate permissions, protect the installation network and manage accounts and passwords carefully.

When using configuration Wi-Fi, also review its credentials. For remote connections, use the project’s authorised access solution, such as Adquio Nexus.

What happens if the Internet connection fails?

Logic running locally on controllers can continue while power, equipment and local communications remain operational. A local Adquio SCADA Server can also maintain the functions designed for the installation network.

Cloud-hosted functions and remote access require connectivity. Define which functions must continue locally and how communication and data recording will recover.

Controllers, screens and modules

9 questions
Can I install the controller outdoors or require IP68?

The protection rating belongs to the specific model. Controllers such as Adquio Mini are intended for panel installation, and their IP20 rating is not IP68.

For outdoor installations, choose an enclosure and design suited to the location, considering moisture, dust, temperature, heat dissipation and power supply. Check the equipment datasheet and the conditions of the complete installation.

Which controllers can use expansion modules?

Select expansions according to their signals and communication protocol, and check controller compatibility. Distinguish physical mounting from data connection: many modules are integrated over an RS-485 Modbus RTU bus.

Compatible controllers, including Adquio Mini and Adquio Lite, can manage modules providing inputs, outputs, relays or probe readings. For example, Adquio Multi IOs Pro combines digital and analogue I/O with PT1000 channels.

What power supply and surge protection do I need?

Observe the installed model’s rated supply, maximum permitted voltage and protection requirements. Do not apply a single voltage limit to every product in the range.

Size a compatible supply and panel protection for the device and connected loads. Fuses and other protection do not replace compliance with the datasheet’s electrical requirements.

What is the USB Host port used for?

Its uses depend on the model, firmware and supported adapters. It can connect peripherals or interfaces supported by the system.

Check support for the required adapter and protocol before choosing it. A USB connector alone does not guarantee compatibility with every radio dongle or converter.

What is the purpose of Micro SD or local storage?

On models that provide it, storage can hold data or support recording and buffering according to the configured software.

How long readings can be retained during an Internet outage depends on the model, available space, recording frequency and application. Review these conditions before specifying storage autonomy.

How many RS-485 ports are available, and what is their reach?

Port count depends on the model: Adquio Mini and Adquio Lite have four ports, while Adquio Micro Server has two. Always check the specific equipment datasheet.

Reach, device count and speed depend on wiring, transceivers and the settings of all bus devices. Compatible ports support Modbus RTU or BACnet MS/TP according to their supported configuration. Do not mix different protocols on the same bus.

Can a controller and its expansions share a power supply?

Yes, when every device supports the same voltage and the supply can deliver the required current. Add the consumption of the modules and any loads powered from it, then size the supply with an appropriate margin.

Review polarities, common references and isolation requirements. Use separate supplies when the equipment or design requires them.

Can I choose between the Casambi app and a custom screen interface?

Yes. Compatible screens can run the Casambi app or a customised dashboard for installation functions. For example, Adquio Screen 10.1″ supports a project-specific interface.

Review each model’s capabilities. The 32″ screen is intended for its dashboard application and should not be treated as equivalent to models that run the Casambi app.

How do I choose between Multi IOs and Multi IOs Pro?

Compare the signals you need. Adquio Multi IOs includes relay outputs; Adquio Multi IOs Pro provides more digital and analogue outputs and adds dedicated digital inputs.

SignalMulti IOsMulti IOs Pro
Configurable AI/DI87
Dedicated DI—10
Digital outputs410
Analogue outputs47
Relay outputs5—
PT100044

Also size the power supply, loads and wiring. Download the Multi IOs Pro datasheet ↗

Signals and probes

3 questions
What are analogue inputs and outputs used for?

They read or send proportional signals. For example, a 0–10 V output can set a compatible valve, damper or regulator, while an input can receive a sensor signal.

Check the manufacturer’s signal range and voltage-to-position relationship. Opening and closing direction is not universal. Use a compatible input or converter for current signals.

What are digital inputs and outputs used for?

Digital inputs receive states such as an alarm, a position or circuit activation. Digital outputs send commands to compatible actuators.

Distinguish transistor outputs from relay contacts. To operate lighting, motors, pumps or other loads, select the correct power interface and observe both the module and load electrical requirements.

Where are PT1000 probes used?

They measure ambient temperature, fluid temperature and other points in an installation. Choose a probe suited to the temperature range, medium and mounting arrangement.

Check that the input supports PT1000 and the probe’s wire count. Overall accuracy depends on the probe, measurement input and wiring; use each component’s specifications.

RS-485 wiring

2 questions
Which cable should I use for Modbus RTU or BACnet MS/TP?

Use twisted-pair cable suitable for RS-485, with shielding where the environment requires it. Select its characteristics according to distance, speed and equipment recommendations.

Observe A and B and any required signal reference. Use a bus topology with short stubs. Follow the installation design for shield and earth connections; signal GND and protective earth must not be assumed to be the same.

When do I need bus termination resistors?

Termination must suit the cable and bus topology. RS-485 commonly uses approximately 120 Ω resistors at the two physical ends of the line.

Check whether equipment already includes termination and how to enable it. Do not add a resistor at every device or duplicate existing termination, which can excessively load the bus. Also review biasing and the manufacturers’ recommendations.

Video and access control

4 questions
Can a camera event trigger automation?

Adquio VisionCore can link compatible video events to Adquio controller variables. Controller logic can use those variables to activate a lighting scene, record a condition or produce an indication.

Check the events provided by each camera and supported by the integration. RTSP video compatibility alone does not guarantee event or analytics compatibility.

Can Adquio disable cameras for privacy or request a photograph?

Yes. The integration with Adquio VisionCore lets the controller request camera activation or deactivation and request photographs. These actions can be included in a control screen, SCADA, BMS or scene.

The interface should show the confirmed state and capture result. Privacy stops the camera’s use in VisionCore; earlier recordings remain available. A disabled camera does not accept new photograph requests.

Can an Adquio screen act as a gateway for locks?

Compatible Android-based Adquio screens with Bluetooth can run a Adquio DoorLink gateway service for nearby locks while retaining their control interface.

Check the model, installed service, Bluetooth coverage and operating conditions. Gateway placement must suit the building’s actual distances and obstacles.

TECHNICAL SUPPORT FOR YOUR PROJECT

Need help with a specific case?

Include the model, connections and behaviour you observe. Our team can review your enquiry with the context of your installation.