Expansions and modules

Adquio 8 PT1000

Add eight inputs for two-wire PT1000 probes. Bring temperature measurement closer to your equipment and integrate readings over RS-485 and Modbus RTU.

Adquio 8 PT1000
adquio 8 PT1000 modbus module

Simple expansion of temperature probes

Adquio 8 PT1000 modbus module

Adquio 8 PT1000 is an eight-input module for two-wire PT1000 temperature probes. It communicates readings over RS-485 and Modbus RTU to an Adquio controller or a compatible master, bringing temperature acquisition closer to the measurement points.

Front connectors and top indicators

  1. 24V DC power supply.
  2. Microswitches for modbus address configuration.
  3. Port 485 protected.
  4. Error indicator.
  5. Indicator of correct connection with the master.
  6. Power indicator.
Vista frontal de módulo modbus de 8 sondas PT1000
vista trasera del módulo modbus de 8 sondas PT1000

Rear connectors

  1. 8 2-position connectors for 8 2-wire PT1000 probes.

Technical specs

Energy

Power supply
24VDC

Consumption
15mA

Connectivity

Port 485
(Compatible with Modbus RTU 9600 / 19200bps)

Inputs

RTD inputs8 · two-wire PT1000

Control

Indicator LEDs
3; Power, On Line and Error


Certifications

Safety and healthEN ISO 13849-1: 2015
EN ISO 13849-2: 2012
EN 62061: 2005 + A1: 2013 + A2: 2015
EN 60950-1: 2006
EN 62311: 2008
EMCEN 61000-6-4: 2007 + A1: 2011
EN 61000-6-2: 2005
ETSI EN 301 489-1 v2.2.0
ETSI EN 301 489-17 v3.2.0
RoHSEN 50581:2012

How to integrate PT1000 probes into your installation

From the physical measurement to control and analysis: follow the temperature data through the installation.

01

PT1000 probes

Connect up to eight two-wire PT1000 probes to the module’s two-position connectors.

02
Adquio 8 PT1000

Adquio 8 PT1000

The module acquires the temperature readings and makes them available over Modbus RTU.

03
Adquio Mini

Adquio controller

Use an Adquio controller with a Modbus RTU master to bring readings into its variables and control logic. Example: Adquio Mini.

Power supply24 V DC
RS-485 communicationModbus RTU · 9600 / 19200 bps
Module addressSet using microswitches

Supply the module with 24 V DC, connect its protected RS-485 port to the Modbus RTU master and set the address and communication speed before checking the readings.

Connect your project with the Adquio ecosystem.

Plan your integration with our engineering team and find the right solution for your installation.

Privacy Overview
Adquio

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Analytics

These cookies measure visits and contact enquiries using Google Analytics and Clientify analytics. They are only enabled if you accept them.

Advertising

These cookies enable Google advertising features and measure their performance. They are only enabled if you accept them.